Before purchasing inspection equipment for a hazardous area, verify that the exact model and configuration are certified for the location’s gas or dust hazard, zone or division, temperature requirements, and operating conditions. Check the equipment nameplate against the certificate and its scope, then confirm the certificate through the issuing scheme or authority’s current records. Do not rely on a product title, a supplier’s general statement, or an IP rating alone. For a borescope, assess every component that will enter or operate in the hazardous area, including the probe, handle, display, power source, and any connected accessories.

You can find more information on our web, so please take a look.

Explosion protection is a match between a classified site and a specific equipment configuration, not a general product feature. The steps below help procurement teams collect evidence, identify mismatches, and resolve questions with a supplier before issuing a purchase order. Final equipment approval should be made with the site’s hazardous-area classification and applicable local rules in view.

Summary: What Buyers Should Verify

  • Match the equipment’s protection marking to the site’s gas or dust classification, zone or division, and required equipment protection level.
  • Confirm that the certificate is valid and explicitly covers the model, options, accessories, and intended use.
  • Check temperature limits, ambient conditions, installation restrictions, and any special conditions of use.
  • For inspection equipment, verify that all components used in the hazardous area are covered—not just the probe or main unit.
  • Ask the supplier for legible nameplate information, certificates, instructions, and written clarification before purchase.

Step 1: Define the Hazardous-Area Requirement

Confirm the site classification first

Request the area classification documents from the site owner or responsible engineering team before selecting equipment. These documents should identify whether the hazard is gas, vapor, mist, or combustible dust, and specify the applicable zone or division, gas or dust group, and temperature requirements. A zone marking and a division marking belong to different classification systems, so do not assume they are interchangeable without an authorized assessment. If the classification is unclear, pause the purchase and ask the site’s hazardous-area authority to clarify it.

For reference, gas Zone 0 describes an area where an explosive gas atmosphere is present continuously, frequently, or for long periods; Zone 1 and Zone 2 describe lower likelihood or duration categories. Dust areas are classified separately, commonly using Zones 20, 21, and 22 in IEC-based systems. These labels are not a substitute for the site’s formal classification or the rules adopted in the country of use.

Identify the protection concept and equipment level

Explosion protection markings can include a protection concept, equipment group, category or Equipment Protection Level (EPL), gas or dust group, and temperature information. The precise combination depends on the certification system and product. For example, a marking that appears suitable for a gas application may not establish suitability for combustible dust, and a certificate for one protection concept does not automatically cover another. Compare the full marking with the site requirement rather than checking only for the words “explosion-proof” or “intrinsically safe.”

Step 2: Read the Nameplate and Match the Exact Model

Obtain a clear photograph of the equipment nameplate and record the complete model number, suffixes, serial or batch information where relevant, and all protection markings. Compare these details with the quotation, datasheet, user instructions, and certificate. A product family may contain versions with different ratings, so a certificate for a similar model is not proof that the offered configuration is covered. Ask the supplier to identify any differences between the certified configuration and the quoted product.

Check the temperature class or maximum surface temperature against the site requirement and the hazardous material’s ignition characteristics. In the commonly used gas temperature-class system, T1 corresponds to a maximum surface temperature of 450°C, while T4 corresponds to 135°C; the lower maximum temperature may be needed for more temperature-sensitive substances. These values are classification limits, not a claim about the equipment’s measured operating temperature in every condition. Verify the applicable marking and certificate conditions for the actual product.

Step 3: Validate the Certificate and Its Scope

Check certificate identity and status

Record the certificate number, issuing body, scheme, issue or revision information, and any stated validity or status. Where an official online register is available, search the certificate number and confirm that the record corresponds to the manufacturer and model being purchased. For IECEx equipment, use the IECEx online certificate system; for ATEX equipment, review the relevant documentation and conformity information for the applicable EU requirements. Certification routes and records vary by market, so verify the requirements for the destination country.

Goto Coantec to know more.

Read the certificate rather than stopping at its cover page. Check its equipment description, model range, protection marking, standards or editions cited, conditions of use, and any schedules or annexes. A certificate may restrict ambient temperature, cable entries, battery type, installation method, or accessory combinations. If a document is incomplete, expired, difficult to authenticate, or inconsistent with the nameplate, request clarification from the supplier or certification body before ordering.

Confirm documents for the destination market

Different markets may require different conformity documentation, markings, and approval routes. ATEX and IECEx documentation may be relevant to many international projects, while North American installations can follow different certification and classification practices. Do not treat one scheme as a universal substitute for another. Ask the end user or local compliance specialist which approvals are accepted at the installation site, and obtain the corresponding documents for the exact equipment offered.

Step 4: Verify the Complete Inspection Equipment Configuration

For a borescope, establish which parts will cross into the classified area and which will remain outside it. The probe may enter a vessel while the handle, display, battery, lighting, or wireless functions are located elsewhere, but that arrangement must be permitted by the equipment instructions and certificate. Confirm whether the certificate covers the complete unit or only a defined component or configuration. Do not infer that an unlisted accessory is acceptable because it connects mechanically or electrically.

Review the intended inspection method, including insertion depth, contact with process residues, cleaning agents, and the possibility of impact or static charge. Check the manufacturer’s instructions for prohibited modifications, charging restrictions, approved batteries, and maintenance requirements. An IP rating describes protection against ingress under specified test conditions; it does not establish explosion protection. Likewise, a rugged enclosure or a low-voltage power supply is not, by itself, evidence of hazardous-area certification.

Step 5: Compare Ratings Against Operating Conditions

Use a simple compliance matrix to compare the site requirement with the equipment evidence. Include atmosphere type, classification, gas or dust group, temperature limit, ambient operating range, ingress requirements, and any task-specific constraints. A rating mismatch in one field can make the equipment unsuitable even when the other fields appear acceptable. Record the source document for each decision so procurement, engineering, and site safety teams can review the same evidence.

Check What to compare Evidence to request
Hazard classification Gas or dust, zone or division, and group Site classification documents and full nameplate marking
Thermal suitability Temperature class or maximum surface temperature Certificate, product marking, and operating instructions
Model coverage Exact model, options, and accessories Certificate schedule and supplier confirmation
Market acceptance Applicable local approval route Required conformity documents for the destination

Common Verification Mistakes

  • Relying on marketing language: “Explosion-proof” in a product description does not establish a particular rating or approval.
  • Checking only the certificate cover: Model limitations and special conditions may appear in schedules or instructions.
  • Assuming a family certificate covers every variant: Confirm the full model code and options against the certificate scope.
  • Confusing ingress protection with explosion protection: IP information addresses enclosure ingress, not ignition risk certification.
  • Ignoring the accessory chain: Batteries, chargers, cables, probes, and add-ons can affect the approved configuration.

Buyer Checklist and Supplier Support

Before releasing a purchase order, send the supplier the site classification and ask for a complete document package for the proposed configuration. Request a legible nameplate image, certificate and schedules, user instructions, conformity documents required for the destination, and a list of approved accessories. Ask the supplier to identify restrictions that could affect inspection, charging, transport, maintenance, or use at the site. Keep written responses with the procurement record and refer unresolved technical questions to the site’s qualified hazardous-area personnel.

At Coantec, we recommend that buyers share the inspection task, required working length, hazardous-area classification, and destination market before requesting a borescope quotation. This allows the equipment configuration and available supporting documents to be reviewed against the application instead of relying on a generic product description. Ask our team to provide the relevant model documentation for evaluation, and have your site authority confirm final suitability before purchase and use.

Conclusion: Verify Evidence Before You Buy

To verify explosion protection ratings, match the exact equipment marking and certificate scope to the site classification, temperature limits, accessories, and local approval requirements. Confirm the certificate’s identity and status, read its restrictions, and assess every borescope component that will be used in the hazardous area. If any model detail or document is unclear, delay approval until the supplier and qualified site personnel resolve the discrepancy. This evidence-based check is the practical next step for reducing compliance uncertainty before purchasing inspection equipment.