Send your supplier a written change request that identifies the original order, states the revised pump duty, explains what has changed, and asks for a written review before production or shipment proceeds. Include the required flow rate and total head, slurry characteristics, operating conditions, and the date the change should take effect. We recommend attaching a revised data sheet and marking every changed value; this gives both parties a clear record to assess design, cost, and schedule implications.
If you are looking for more details, kindly visit our website.
A duty change can affect more than the pump’s nominal capacity. Depending on the pump design and the revised conditions, it may require a review of hydraulic selection, motor power, wetted materials, seals, connections, or other supplied components. The process below helps you communicate the change without assuming that the existing configuration will remain suitable.
What to Include in a Pump Duty Change Request
Start with information that lets your supplier identify the order and understand the operating point you now need. Use the same units and definitions as the original quotation or approved data sheet wherever possible. If a value is unknown or still being confirmed, label it as provisional rather than presenting it as final.
- Order identification: Purchase order number, quotation or project reference, pump tag, and the supplier’s drawing or data-sheet revision.
- Original and revised duty: Required flow rate and total dynamic head, including the units and the conditions under which each value applies.
- Slurry details: Solids concentration and whether it is expressed by mass or volume, particle size or distribution if known, particle shape where relevant, and any changes in abrasiveness or corrosiveness.
- Operating conditions: Continuous or intermittent operation, expected operating hours, suction conditions, liquid temperature, and any changes to the process or installation.
- Timing and approval: When the revised duty is needed, whether production has started, and who is authorized to approve cost or schedule changes.
Attach supporting documents where available, such as an updated process data sheet, piping information, or a marked-up supplier drawing. Clearly identify which document is the current version and withdraw or mark superseded versions to reduce the risk of conflicting instructions. If the change affects only one operating case, state whether the pump must serve that case alone or operate across multiple conditions.
Step-by-Step: Record the Change and Get It Reviewed
1. Establish the approved baseline
Before describing the change, record what was originally ordered and approved. Copy the duty point, fluid information, materials, motor details, connection requirements, and relevant document revisions from the purchase record or approved technical submission. This baseline helps the supplier distinguish a genuine scope change from a clarification or correction.
Do not rely on a brief description such as “increase capacity” or “pump heavier slurry.” Those phrases do not define a design point or explain which operating conditions have changed. If the original figures are unclear, ask the supplier to confirm the approved baseline before issuing revised requirements.
2. State each revised value clearly
Present original and revised values side by side, with units and a short explanation. For example, a buyer might show an illustrative change from 30 m³/h to 36 m³/h in required flow, while separately identifying a head change from 22 m to 25 m. These figures are examples of how to format a change request, not a recommended pump duty or a performance claim.
| Parameter | Approved value | Revised value | Notes or basis |
|---|---|---|---|
| Flow rate | Enter original value and unit | Enter requested value and unit | State process requirement or operating case |
| Total head | Enter original value and unit | Enter requested value and unit | Clarify the system conditions used |
| Slurry concentration | Enter original value and basis | Enter revised value and basis | Specify mass or volume percentage |
| Required date | Enter current committed date | Enter revised need date | Identify any project milestone |
3. Describe the slurry and operating context
A flow and head change alone may not describe the revised duty sufficiently. Tell the supplier whether solids concentration, particle characteristics, temperature, chemistry, suction arrangement, or operating pattern has changed. Where concentration is given as a percentage, specify whether it is by mass or volume; the two bases are not interchangeable.
Also identify whether the revised figures are normal, minimum, maximum, or occasional conditions. If you need the pump to handle more than one operating point, list each point and indicate how often or under what process condition it occurs. The supplier can then assess the requested scope against the information provided and identify any data still needed.
4. Ask for a documented technical and commercial review
Request written confirmation of whether the revised duty can be accommodated by the existing selection or whether the supplier recommends a revised configuration. Ask the supplier to identify any affected components or documents, and to state any changes to price, manufacturing status, delivery timing, or approval requirements. These impacts should be confirmed for your specific order rather than assumed from the duty change alone.
Goto RUIBANG to know more.
Where needed, ask for an updated selection sheet, drawing, bill of materials, or other applicable technical document. Do not treat an informal discussion as authorization to alter an order. Record who approved the change and ensure the purchase order or formal change order reflects the agreed scope.
5. Close the revision loop
When the supplier responds, compare the revised documents with your request and check that the duty, fluid data, and scope match your intended operating conditions. Confirm the document revision and approval status in writing. Keep the original and revised records together so that project, purchasing, operations, and maintenance teams can identify which configuration was accepted.
Key Decisions Before You Submit the Request
Is this a changed requirement or a corrected input?
A changed requirement means the process need has shifted after the order was placed. A correction means information in the original submission was inaccurate or incomplete. Tell the supplier which situation applies, because it can affect how the request is evaluated and how responsibility, cost, or schedule is discussed.
Does the revised duty cover one point or a wider range?
A single revised operating point is different from a requirement to operate across a range of flows or slurry conditions. State the expected range and identify any limits that are important to your process. If you do not know the limits, ask the supplier what additional process information is needed to review them.
Has production or procurement already progressed?
Tell the supplier whether the pump is still under technical review, in production, completed, or already shipped, if that status is known. The available options and potential impacts may depend on order progress and the specific configuration. Ask for a status-based response rather than assuming that a change can be incorporated without affecting cost or delivery.
Common Documentation Mistakes to Avoid
- Sending only a new flow rate: Include head, slurry properties, operating conditions, and the relevant original values so the request can be assessed in context.
- Omitting units or percentage basis: State units for each value and specify whether solids concentration is by mass or volume.
- Using unclear revision control: Put the revision, date, and order reference on each updated document, and identify superseded files.
- Assuming the existing pump remains suitable: Request a supplier review; a changed duty may require evaluation of the selection and associated components.
- Approving informally: Obtain written confirmation of technical scope and commercial or schedule impacts before treating the change as accepted.
How RUIBANG Can Support the Review
At RUIBANG, we use the order reference and revised operating information to understand what has changed and what requires confirmation. For a custom slurry or mud pump order, share the original approved data alongside the updated duty and slurry details. We can review the information available, identify questions that need resolution, and discuss whether revised technical documents or a formal order change are required.
To make the review more efficient, send one consolidated change package rather than separate, untracked messages. Include a concise change summary, marked-up data sheet, current process information, and your required decision or delivery date. If any information is not yet confirmed, label it clearly so the review can distinguish confirmed requirements from assumptions.
Summary and Next Steps
To document duty changes after a custom pump order, establish the approved baseline, list each revised value with units, explain the slurry and operating context, and request written technical and commercial confirmation. Keep revisions traceable and obtain the appropriate approval before the changed scope is treated as final. This approach gives your supplier the information needed to review the request while creating a clear record for purchasing and project teams.
Before contacting RUIBANG, gather your order number, approved pump data, revised duty point, slurry characteristics, installation or operating changes, and required timing. Send the package to your sales or technical contact and ask for confirmation of the reviewed configuration, document revision, and any order impacts. If you are preparing a new change request, we can help you identify which information is needed for the next review.
For more How to Document Duty Changes After a Custom Pump Orderinformation, please contact us. We will provide professional answers.